The length of Evans et al. (2003) necessitated transfer of several less germane sections to this alternate forum to meet that venue’s needs. These sections include a description of the development of Figure 1, the plot of spatial variability so critical to the argument for dense arrays of strong-motion instruments; the description of the rapid, integer, computational method for PGV used in the TREMOR instrument (the Oakland instrument, the commercial prototype, and the commercial instrument); siting methods and strategies used for Class B TREMOR instruments and those that can be used for Class C instruments to preserve the cost advantages of such systems; and some general discussion of MEMS accelerometers, including a comparative Table with representative examples of Class A, B and C MEMS devices. (“MEMS” means “Micro-ElectroMechanical” Systems—“micromachined” sensors, generally of silicon. Classes A, B, and C are defined in Table 1.)

Publication Year 2003
Title Additional information for “TREMOR: A Wireless, MEMS Accelerograph for Dense Arrays” (Evans et al., 2003)
DOI 10.3133/ofr03159
Authors John R. Evans, Robert H. Hamstra, Paul Spudich, Christoph Kundig, Patrick Camina, John A. Rogers
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Open-File Report
Series Number 2003-159
Index ID ofr03159
Record Source USGS Publications Warehouse
USGS Organization Earthquake Science Center