A multi-residue method for the analysis of pesticides and pesticide degradates in water using HLB solid-phase extraction and gas chromatography-ion trap mass spectrometry
January 1, 2008
A method was developed for the analysis of over 60 pesticides and degradates in water by HLB solid-phase extraction and gas-chromatography/mass spectrometry. Method recoveries and detection limits were determined using two surface waters with different dissolved organic carbon (DOC) concentrations. In the lower DOC water, recoveries and detection limits were 80%–108% and 1–12 ng/L, respectively. In the higher DOC water, the detection limits were slightly higher (1–15 ng/L). Additionally, surface water samples from four sites were analyzed and 14 pesticides were detected with concentrations ranging from 4 to 1,200 ng/L.
Citation Information
Publication Year | 2008 |
---|---|
Title | A multi-residue method for the analysis of pesticides and pesticide degradates in water using HLB solid-phase extraction and gas chromatography-ion trap mass spectrometry |
DOI | 10.1007/s00128-007-9332-2 |
Authors | M.L. Hladik, K.L. Smalling, K.M. Kuivila |
Publication Type | Article |
Publication Subtype | Journal Article |
Series Title | Bulletin of Environmental Contamination and Toxicology |
Index ID | 70033257 |
Record Source | USGS Publications Warehouse |
USGS Organization | California Water Science Center; Toxic Substances Hydrology Program |