Contamination movement around a permeable reactive barrier at Solid Waste Management Unit 12, Naval Weapons Station Charleston, North Charleston, South Carolina, 2009

January 1, 2010

The U.S. Geological Survey and the Naval Facilities Engineering Command Southeast investigated natural and engineered remediation of chlorinated volatile organic compound groundwater contamination at Solid Waste Management Unit 12 at the Naval Weapons Station Charleston, North Charleston, South Carolina, beginning in 2000. In early 2004, groundwater contaminants began moving around the southern end of a permeable reactive barrier (PRB) installed by a consultant in December 2002. The PRB is a 130-foot-long and 3-foot-wide barrier consisting of varying amounts of zero-valent iron with or without sand mixture. Contamination moving around the PRB probably has been transported at least 75 feet downgradient from the PRB at a rate of about 15 to 29 feet per year.
The diversion of contamination around the southern end of the PRB may be due to construction difficulties associated with the PRB installation or to reduced permeability in the PRB. An event that took place during installation of the PRB, which may have caused permeability loss, was the collapse and subsequent abandonment of a 110-foot-long trench originally designed to be the PRB on November 11, 2002, approximately 25 feet upgradient (west) from the final PRB. Guar gum with antimicrobial preservative in a polymer slurry had been used to stabilize the abandoned trench prior to collapse and was only partially recovered. Residual guar gum can cause permeability reduction in a PRB. It also is possible that permeability reduction took place within the PRB by slow degradation of the guar gum slurry or mineral precipitation. Despite the likely permeability reduction in and near the PRB immediately following installation, there is evidence that contaminants moved through the PRB and were degraded, consistent with the planned purpose of the PRB.
Volatile organic compound contamination in groundwater downgradient from the PRB is subject to attenuation by phytovolatilization, sorption, and biodegradation. Pulses of contamination increases have been observed in some monitoring wells downgradient from the PRB. The pulses may reflect downgradient transport of contaminant pulses; however, lateral shifting of the plume is a more likely explanation for the concentration changes at well 12MW-12S.
The ability to monitor the fate and behavior of the plume in the forest is severely limited because the present axis of maximum contamination in that area bypasses all but one of the existing monitoring wells (12MW-12S). Moreover, the 2009 data indicate that there are no optimally placed sentinel wells in the probable path of contaminant transport. Thus the monitoring network is no longer adequate to monitor the groundwater contamination downgradient from the PRB.

Publication Year 2010
Title Contamination movement around a permeable reactive barrier at Solid Waste Management Unit 12, Naval Weapons Station Charleston, North Charleston, South Carolina, 2009
DOI 10.3133/sir20105086
Authors Don A. Vroblesky, Matthew D. Petkewich, Kevin J. Conlon
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Scientific Investigations Report
Series Number 2010-5086
Index ID sir20105086
Record Source USGS Publications Warehouse
USGS Organization South Atlantic Water Science Center