Skip to main content
U.S. flag

An official website of the United States government

Evaluation of the 8310-N-S manufactured by Sutron–Results of bench, temperature, and field deployment testing

January 7, 2016

The Sutron 8310-N-S (8310) data collection platform (DCP) manufactured by Sutron Corporation was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to the manufacturer’s specifications for recording and transmitting data. The 8310-N-S is a National Electrical Manufacturers Association (NEMA)-enclosed DCP with a built-in Geostationary Operational Environmental Satellite transmitter that operates over a temperature range of −40 to 60 degrees Celsius (°C). The evaluation procedures followed and the results obtained are described in this report for bench, temperature chamber, and outdoor deployment testing. The three units tested met the manufacturer’s stated specifications for the tested conditions, but two of the units had transmission errors either during temperature chamber or deployment testing. During outdoor deployment testing, 6.72 percent of transmissions by serial number 1206109 contained errors, resulting in missing data. Transmission errors were also observed during temperature chamber testing with serial number 1208283, at an error rate of 3.22 percent. Overall, the 8310 has good logging capabilities, but the transmission errors are a concern for users who require reliable telemetered data.

Publication Year 2016
Title Evaluation of the 8310-N-S manufactured by Sutron–Results of bench, temperature, and field deployment testing
DOI 10.3133/ofr20151210
Authors Gerald A. Kunkle
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Open-File Report
Series Number 2015-1210
Index ID ofr20151210
Record Source USGS Publications Warehouse
USGS Organization Office of Surface Water