Hydrologic effects of the Tampa Bypass Canal
Flood water of the Hillsborough River will be diverted at a point upstream from areas of flood-plain encroachment in the cities of Tampa and Temple Terrace into nearby McKay Bay by means of the Tampa Bypass Canal System, which is being built by the U. S. Army Corps of Engineers through an area east of Tampa. The canal system will breach the underlying artesian Floridan aquifer in places where the potentiometric surface of the aquifer is at or near land surface, causing drawdowns over a wide area and diverting flow from other parts of the hydrologic system. An investigation by the U. S. Geological Survey in cooperation with the Corps of Engineers in conjunction with the Southwest Florida Water Management District was made to assess the hydrologic effects of the canal system and to determine whether an additional water-level control structure could reduce significantly the hydrologic effects of the canal system. The additional structure would maintain the pool level in the Eureka Springs and Harney Flats areas at a 5-foot higher level than without the structure, reducing drawdown in and discharge from the Floridan aquifer in these areas. The assessment of hydrologic effects was based on water-level conditions of the May 1972 low-water period. The assessment was made for a seasonal low--water period, because the effect that the discharge into the canal system will have on ground-water discharge at other places in the hydrologic system and on flow in the Hillsborough River will be most critical during the dry season.
The canal system, as presently designed, will lower the potentiometric surface of the Floridan aquifer by 1 foot or more over an area of about 92 square miles with C-132 (Thonotosassa Canal) included in the system and about 48 square miles without C-132; discharge from the aquifer into the canal system will be 22 million gallons per day with C-132 and 15 million gallons per day without C-132. The discharge into the canal system will cause a decrease in the present (pre-canal system) discharge from the Floridan aquifer to other parts of the hydrologic system. If another control structure is added to the canal system near Buffalo Avenue, the area of drawdown (1 foot or more) of the potentiometric surface will be less by 45 percent and the discharge less by 40 percent with C-132 included in the system; without C-132, the area of drawdown will be less by 50 percent and the discharge less by 45 percent. Because certain segments of the canal system were assumed to be in direct hydraulic connection with the Floridan aquifer along their entire length, an assumption which is valid for only part of their length, the values represent a maximum condition.
Citation Information
| Publication Year | 1974 |
|---|---|
| Title | Hydrologic effects of the Tampa Bypass Canal |
| DOI | 10.3133/ofr74257 |
| Authors | Louis H. Motz |
| Publication Type | Report |
| Publication Subtype | USGS Numbered Series |
| Series Title | Open-File Report |
| Series Number | 74-257 |
| Index ID | ofr74257 |
| Record Source | USGS Publications Warehouse |