Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of selected carbamate pesticides in water by high-performance liquid chromatography

January 1, 1994

As part of its primary responsibility concerning water as a national resource, the U.S. Geological Survey collects and analyzes samples of ground water and surface water to determine water quality. This report describes the method used since June 1987 to determine selected total-recoverable carbamate pesticides present in water samples. High- performance liquid chromatography is used to separate N-methyl carbamates, N-methyl carbamoyloximes, and an N-phenyl carbamate which have been extracted from water and concentrated in dichloromethane. Analytes, surrogate compounds, and reference compounds are eluted from the analytical column within 25 minutes. Two modes of analyte detection are used: (1) a photodiode-array detector measures and records ultraviolet-absorbance profiles, and (2) a fluorescence detector measures and records fluorescence from an analyte derivative produced when analyte hydrolysis is combined with chemical derivatization. Analytes are identified and confirmed in a three-stage process by use of chromatographic retention time, ultraviolet (UV) spectral comparison, and derivatization/fluorescence detection. Quantitative results are based on the integration of single-wavelength UV-absorbance chromatograms and on comparison with calibration curves derived from external analyte standards that are run with samples as part of an instrumental analytical sequence. Estimated method detection limits vary for each analyte, depending on the sample matrix conditions, and range from 0.5 microgram per liter to as low as 0.01 microgram per liter. Reporting levels for all analytes have been set at 0.5 microgram per liter for this method. Corrections on the basis of percentage recoveries of analytes spiked into distilled water are not applied to values calculated for analyte concentration in samples. These values for analyte concentrations instead indicate the quantities recovered by the method from a particular sample matrix.

Publication Year 1994
Title Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of selected carbamate pesticides in water by high-performance liquid chromatography
DOI 10.3133/ofr93650
Authors S.L. Werner, S.M. Johnson
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Open-File Report
Series Number 93-650
Index ID ofr93650
Record Source USGS Publications Warehouse
USGS Organization National Water Quality Laboratory