Percentage entrainment of constituent loads in urban runoff, south Florida
January 1, 1985
Runoff quantity and quality data from four urban basins in south Florida were analyzed to determine the entrainment of total nitrogen, total phosphorus, total carbon, chemical oxygen demand, suspended solids, and total lead within the stormwater runoff. Land use of the homogeneously developed basins are residential (single family), highway, commercial, and apartment (multifamily).
A computational procedure was used to calculate, for all storms that had water-quality data, the percentage of constituent load entrainment in specified depths of runoff. The plot of percentage of constituent load entrained as a function of runoff is termed the percentage-entrainment curve.
Percentage-entrainment curves were developed for three different source areas of basin runoff: (1) the hydraulically effective impervious area, (2) the contributing area, and (3) the drainage area. With basin runoff expressed in inches over the contributing area, the depth of runoff required to remove 90 percent of the constituent load ranged from about 0.4 inch to about 1.4 inches; and to remove 80 percent, from about 0.3 to 0.9 inch.
Analysis of variance, using depth of runoff from the contributing area as the response variable, showed that the factor 'basin' is statistically significant, but that the factor 'constituent' is not statistically significant in the forming of the percentage-entrainment curve. Evidently the sewerage design, whether elongated or concise in plan dictates the shape of the percentage-entrainment curve.
The percentage-entrainment curves for all constituents were averaged for each basin and plotted against basin runoff for three source areas of runoff-the hydraulically effective impervious area, the contributing area, and the drainage area. The relative positions of the three curves are directly related to the relative sizes of the three source areas considered.
One general percentage-entrainment curve based on runoff from the contributing area was formed by averaging across both constituents and basins. Its coordinates are: 0.25 inch of runoff for 50-percent entrainment, 0.65 inch of runoff for 80-percent entrainment, and 0.95 inch of runoff for 90-percent entrainment. The general percentage-entrainment curve based on runoff from the hydraulically effective impervious area has runoff values of 0.35, 0.95, 1.6 inches, respectively.
Citation Information
Publication Year | 1985 |
---|---|
Title | Percentage entrainment of constituent loads in urban runoff, south Florida |
DOI | 10.3133/wri844329 |
Authors | R. A. Miller |
Publication Type | Report |
Publication Subtype | USGS Numbered Series |
Series Title | Water-Resources Investigations Report |
Series Number | 84-4329 |
Index ID | wri844329 |
Record Source | USGS Publications Warehouse |
USGS Organization | Caribbean-Florida Water Science Center |