The selenium content of U.S.G.S. standard rocks
Selenium was determined in duplicate portions from three bottles of six U.S.G.S. standard rocks by a spect rofluorimetric procedure. The following averages, as p.p.m. Se, were obtained: PCC-1, 0.031; GSP-1, 0.088; BCR-1, 0.12; SCo-1, 0.91; MAG-1, 1.3; and SGR-1, 3.7. One-way analysis of variance of the several sets of data showed no significant differences in the selenium content among bottles of any specific rock; these samples may be accepted as homogeneous for their selenium contents by this analytical method.
Citation Information
| Publication Year | 1973 |
|---|---|
| Title | The selenium content of U.S.G.S. standard rocks |
| DOI | 10.1016/0009-2541(73)90030-2 |
| Authors | M. M. Schnepfe, F.J. Flanagan |
| Publication Type | Article |
| Publication Subtype | Journal Article |
| Series Title | Chemical Geology |
| Index ID | 70009774 |
| Record Source | USGS Publications Warehouse |