Simulation of an aquifer test on the Tesuque Pueblo Grant, New Mexico
January 1, 1980
An aquifer test was designed and conducted in the anisotropic dipping beds of the Tesuque Formation on the Tesuque Pueblo Grant, N.M. The three-dimensional digital model used to analyze the test approximated the response to the test. The analysis of the geohydrology of the test site in combination with the model calibration has provided estimates of average aquifer characteristics for the group of beds penetrated at the test site; the hydraulic conductivity parallel to the beds is about 2 feet per day, the hydraulic conductivity normal to the beds is about 0.0001 foot per day or lower, the specific yield is about 0.15, and the specific storage is about 0.000002 per foot. (USGS)
Citation Information
Publication Year | 1980 |
---|---|
Title | Simulation of an aquifer test on the Tesuque Pueblo Grant, New Mexico |
DOI | 10.3133/ofr801022 |
Authors | Glenn A. Hearne |
Publication Type | Report |
Publication Subtype | USGS Numbered Series |
Series Title | Open-File Report |
Series Number | 80-1022 |
Index ID | ofr801022 |
Record Source | USGS Publications Warehouse |