Skip to main content
U.S. flag

An official website of the United States government

Water reuse systems: A review of the principal components

January 1, 1988

Principal components of water reuse systems include ammonia removal, disease control, temperature control, aeration, and particulate filtration. Effective ammonia removal techniques include air stripping, ion exchange, and biofiltration. Selection of a particular technique largely depends on site-specific requirements (e.g., space, existing water quality, and fish densities). Disease control, although often overlooked, is a major problem in reuse systems. Pathogens can be controlled most effectively with ultraviolet radiation, ozone, or chlorine. Simple and inexpensive methods are available to increase oxygen concentration and eliminate gas supersaturation, these include commercial aerators, air injectors, and packed columns. Temperature control is a major advantage of reuse systems, but the equipment required can be expensive, particularly if water temperature must be rigidly controlled and ambient air temperature fluctuates. Filtration can be readily accomplished with a hydrocyclone or sand filter that increases overall system efficiency. Based on criteria of adaptability, efficiency, and reasonable cost, we recommend components for a small water reuse system.

Publication Year 1988
Title Water reuse systems: A review of the principal components
DOI 10.1577/1548-8640(1988)050<0001:WRSARO>2.3.CO;2
Authors G. Lucchetti, G.A. Gray
Publication Type Article
Publication Subtype Journal Article
Series Title Progressive Fish-Culturist
Index ID 70162039
Record Source USGS Publications Warehouse
USGS Organization Western Fisheries Research Center