X-ray spectrographic determination of cesium and rubidium
January 1, 1957
An x-ray spectrographic method for the determination of rubidium and cesium was developed, using the internal-standard method and a four-channel flat-crystal spectrograph. The sensitivity is within 0.1% for cesia and 0.02% for rubidia; the precision is within 10% of the amount present. Results agree well with those obtained by flame photometry and by radio-activation.
Citation Information
Publication Year | 1957 |
---|---|
Title | X-ray spectrographic determination of cesium and rubidium |
DOI | 10.1021/ac60129a009 |
Authors | J. M. Axelrod, I. Adler |
Publication Type | Article |
Publication Subtype | Journal Article |
Series Title | Analytical Chemistry |
Index ID | 70010720 |
Record Source | USGS Publications Warehouse |