Skip to main content
U.S. flag

An official website of the United States government

Accumulated wastewater and wastewater-derived predicted environmental concentrations of per- and polyfluoroalkyl substances for the Illinois River Basin

November 13, 2026

This data release provides wastewater discharge and per‑ and polyfluoroalkyl substances (PFAS) monitoring data from wastewater treatment plant (WWTP) outfalls used to compute accumulated wastewater percentage (ACCWW%) and wastewater-derived predicted environmental concentrations (PECs) of PFAS across all NHDPlus V2 flowlines in the Illinois River Basin (IRB; Table1_IRB_Flowlines.csv). Streamflow for each flowline was obtained from the NHDPlus V2 Enhanced Unit Runoff Method (EROM), representing long‑term mean‑monthly and mean-annual conditions from 1971–2000.

Average monthly wastewater discharges and PFAS concentrations were compiled from Discharge Monitoring Reports (DMRs) accessed through the U.S. Environmental Protection Agency’s (USEPA) Integrated Compliance Information System–NPDES (ICIS‑NPDES) via the ECHO database. All quality‑assurance procedures used to remove inaccurate or anomalous DMR values—including handling repeated values, inconsistent units, anomalously high concentrations or flows, and nondetect indicators—are documented in the process steps (Table2_IRB_Facilities.csv; Table3_Facility_PFAS_DMRs.csv).

PFAS typical pollutant concentrations (TPCs) were developed for eight PFAS compounds (perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorobutanesulfonic acid (PFBS), perfluorohexanesulfonic acid (PFHxS), and perfluorooctanesulfonic acid (PFOS)), as well as the sum of the eight PFAS using reported DMR concentrations and Standard Industrial Classification (SIC) codes to relate concentrations to specific facilities (Table4_PFAS_TPCs.csv). Concentrations were standardized to consistent units, nondetects were flagged and retained, and percentile estimates (5th, 25th, 50th, 75th, and 95th) were generated for use in PFAS PEC calculations using the Kaplan-Meier method. Monthly PFAS loads for each outfall were then calculated by multiplying the average monthly discharge volume by industry‑specific TPCs.

At each flowline, average monthly ACCWW% was calculated as total accumulated wastewater (both upstream contributions and local flowline discharges) divided by the sum of EROM streamflow and accumulated wastewater discharge. PFAS loads were routed through the NHDPlus stream network and converted into PECs (ng/L) by dividing predicted PFAS loads by the sum of EROM streamflow and accumulated wastewater discharge. Results are provided for all flowlines (Table5_IRB_Results.csv) and for only those with non‑zero accumulated wastewater contributions (Table6_IRB_Nonzero_Results.csv) with NHDPlus V2 common identifiers for spatial reference. An R script is included to reproduce the results shown within this data release.

Publication Year 2026
Title Accumulated wastewater and wastewater-derived predicted environmental concentrations of per- and polyfluoroalkyl substances for the Illinois River Basin
DOI 10.5066/P14HLEH4
Authors Samuel A Miller, Charles V Cigrand, Robert P Kostynick, Larry B Barber
Product Type Data Release
Record Source USGS Asset Identifier Service (AIS)
USGS Organization Central Midwest Water Science Center - Rolla, MO Office
Rights This work is marked with CC0 1.0 Universal
Was this page helpful?