Skip to main content
U.S. flag

An official website of the United States government

Delineation of faults, fractures, foliation, and ground-water-flow zones in fractured-rock, on the southern part of Manhattan, New York, through use of advanced borehole-geophysical techniques

January 1, 2004

Advanced borehole-geophysical techniques were used to assess the geohydrology of crystalline bedrock in 20 boreholes on the southern part of Manhattan Island, N.Y., in preparation for construction of a third water tunnel for New York City. The borehole-logging techniques included natural gamma, single-point resistance, short-normal resistivity, mechanical and acoustic caliper, magnetic susceptibility, borehole-fluid temperature and resistivity, borehole-fluid specific conductance, dissolved oxygen, pH, redox, heatpulse flowmeter (at selected boreholes), borehole deviation, acoustic and optical televiewer, and borehole radar (at selected boreholes). Hydraulic head and specific-capacity test data were collected from 29 boreholes. The boreholes penetrated gneiss, schist, and other crystalline bedrock that has an overall southwest to northwest-dipping foliation. Most of the fractures penetrated are nearly horizontal or have moderate- to high-angle northwest or eastward dip azimuths. Foliation dip within the potential tunnel-construction zone is northwestward and southeastward in the proposed North Water-Tunnel, northwestward to southwestward in the proposed Midtown Water-Tunnel, and northwestward to westward dipping in the proposed South Water-Tunnel. Fracture population dip azimuths are variable. Heat-pulse flowmeter logs obtained under pumping and nonpumping (ambient) conditions, together with other geophysical logs, indicate transmissive fracture zones in each borehole. The 60-megahertz directional borehole-radar logs delineated the location and orientation of several radar reflectors that did not intersect the projection of the borehole.

Fracture indexes range from 0.12 to 0.93 fractures per foot of borehole. Analysis of specific-capacity tests from each borehole indicated that transmissivity ranges from 2 to 459 feet squared per day; the highest transmissivity is at the Midtown Water-Tunnel borehole (E35ST-D).

Publication Year 2004
Title Delineation of faults, fractures, foliation, and ground-water-flow zones in fractured-rock, on the southern part of Manhattan, New York, through use of advanced borehole-geophysical techniques
DOI 10.3133/ofr20041232
Authors Frederick Stumm, Anthony Chu, Jack Monti
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Open-File Report
Series Number 2004-1232
Index ID ofr20041232
Record Source USGS Publications Warehouse
USGS Organization New York Water Science Center