Evaluation of borehole geophysical logs and hydraulic tests, phase III, at AIW Frank/Mid-County Mustang Superfund Site, Chester County, Pennsylvania

January 1, 2001

Borehole geophysical logs, heatpulse-flowmeter measurements, and aquifer-isolation tests were used to characterize the ground-water-flow system at the AIW Frank/Mid-County Mustang Superfund Site. The site is underlain by fractured carbonate rocks. Caliper, natural-gamma, single-point-resistance, fluid-resistivity, and fluid-temperature logs were run in six wells, and an acoustic borehole televiewer and borehole deviation log was run in one well. The direction and rate of borehole-fluid movement was measured with a high-resolution heatpulse flowmeter for both nonpumping and pumping conditions in four wells. The heatpulse-flowmeter measurements showed flow within the borehole during nonpumping conditions in three of the four wells tested. Flow rates up to 1.4 gallons per minute were measured. Flow was upward in one well and both upward and downward in two wells. Aquifer-isolation (packer) tests were conducted in four wells to determine depth-discrete specific capacity values, to obtain depth-discrete water samples, and to determine the effect of pumping an individual fracture or fracture zone in one well on water levels in nearby wells. Water-level data collected during aquifer-isolation tests were consistent with and confirmed interpretations of borehole geophysical logs and heatpulse-flowmeter measurements. Seven of the 13 fractures identified as water-producing or water-receiving zones by borehole geophysical methods produced water at a rate equal to or greater than 7.5 gallons per minute when isolated and pumped. The specific capacities of isolated fractures range over three orders of magnitude, from 0.005 to 7.1 gallons per minute per foot. Vertical distribution of specific capacity between land surface and 298 feet below land surface is not related to depth. The four highest specific capacities, in descending order, are at depths of 174-198, 90-92, 118-119, and 34-37 feet below land surface.

Publication Year 2001
Title Evaluation of borehole geophysical logs and hydraulic tests, phase III, at AIW Frank/Mid-County Mustang Superfund Site, Chester County, Pennsylvania
DOI 10.3133/wri014004
Authors Ronald A. Sloto
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Water-Resources Investigations Report
Series Number 2001-4004
Index ID wri014004
Record Source USGS Publications Warehouse
USGS Organization Pennsylvania Water Science Center