Behavior of a chlorinated ethene plume following source-area treatment with Fenton's reagent
Monitoring data collected over a 6‐year period show that a plume of chlorinated ethene–contaminated ground water has contracted significantly following treatment of the contaminant source area using in situ oxidation. Prior to treatment (1998), concentrations of perchloroethene (PCE) exceeded 4500 μg/L in a contaminant source area associated with a municipal landfill in Kings Bay, Georgia. The plume emanating from this source area was characterized by vinyl chloride (VC) concentrations exceeding 800 μg/L. In situ oxidation using Fenton's reagent lowered PCE concentrations in the source area below 100 μg/L, and PCE concentrations have not rebounded above this level since treatment. In the 6 years following treatment, VC concentrations in the plume have decreased significantly. These concentration declines can be attributed to the movement of Fenton's reagent–treated water downgradient through the system, the cessation of a previously installed pump‐and‐treat system, and the significant natural attenuation capacity of this anoxic aquifer. While in situ oxidation briefly decreased the abundance and activity of microorganisms in the source area, this activity rebounded in
Citation Information
| Publication Year | 2005 |
|---|---|
| Title | Behavior of a chlorinated ethene plume following source-area treatment with Fenton's reagent |
| DOI | 10.1111/j.1745-6592.2005.0020.x |
| Authors | F. H. Chapelle, P. M. Bradley, C.C. Casey |
| Publication Type | Article |
| Publication Subtype | Journal Article |
| Series Title | Ground Water Monitoring and Remediation |
| Index ID | 70029386 |
| Record Source | USGS Publications Warehouse |
| USGS Organization | Toxic Substances Hydrology Program |