Skip to main content
U.S. flag

An official website of the United States government

Determining anisotropic transmissivity using a simplified Papadopulos method

January 1, 2006

The straight-line method presented by Papadopulos requires a minimum of three observation wells for determining the transmissivity tensor of a homogeneous and anisotropic aquifer. A simplification of this method was developed for fractured aquifers where the principal directions of the transmissivity tensor are known prior to implementation, such as when fracture patterns on outcropping portions of the aquifer may be used to infer the principal directions. This new method assumes that observation wells are drilled along the two principal directions from the pumped well, thus reducing the required number of observation wells to two. This method was applied for an aquifer test in the fractured Navajo Sandstone of southwestern Utah and yielded minimum and maximum principal transmissivity values of 70 and 1800 m 2/d, respectively, indicating an anisotropy ratio of ???24 to 1.

Publication Year 2006
Title Determining anisotropic transmissivity using a simplified Papadopulos method
DOI 10.1111/j.1745-6584.2006.00210.x
Authors V.M. Heilweil, P. A. Hsieh
Publication Type Article
Publication Subtype Journal Article
Series Title Ground Water
Index ID 70028471
Record Source USGS Publications Warehouse
Was this page helpful?