Skip to main content
U.S. flag

An official website of the United States government

Integrated analysis of flow, temperature, and specific-conductance logs and depth-dependent water-quality samples from three deep wells in a fractured-sandstone aquifer, Ventura County, California

May 15, 2009

Analysis of flow, temperature, and specific-conductance logs and depth-dependent water-quality samples collected under ambient and pumped conditions provided a preliminary delineation of flow zones and water quality in three deep abandoned water-supply wells. The integrated analysis was completed as part of the characterization of a fractured-sandstone aquifer in the mountainous setting of the Santa Susana Field Laboratory in southern Ventura County, California.

In the deepest well, which was 1,768 feet deep and had the highest specific capacity (120 gallons per minute per foot), flow zones were detected at 380 feet (base of casing) and at 440, 595, and 770 feet in the open hole. Under ambient conditions, measured flow was downward from the 380- and 440-foot zones to the 595- and 770-foot zones. Under pumped conditions, most of flow was contributed by the 595-foot zone. Flow from the 380- and 440-foot zones appeared to have lower specific conductance and higher trichloroethylene concentrations than that from the 595-foot zone.

In the shallowest well, which was reportedly 940 feet deep but only logged to 915 feet due to blockage, flow zones were detected behind the perforated casing and at 867 feet in the open hole. Under ambient conditions, downward and upward flows appeared to exit at a zone behind the perforated casing at 708 feet. Most of the pumped flow was contributed from zones behind the perforated casing between 565 and 708 feet. Pumped flow also was contributed by zones at 867 feet and below the logged depth. Volatile organic compounds were not detected in the ambient and pumped flows.

In the third well, which was 1,272 feet deep and had the lowest specific capacity (3.6 gallons per minute per foot), flow zones were detected in the open hole above and just below the water level near 337 feet and at 615, 785, 995, and 1,070 feet. Under ambient conditions, measured flow in well was downward from the shallowmost zones to the 995-foot zone. Fracture zones at 615, 785, and 995 feet each contributed about one-third of the pumped flow measured below the pump. Volatile organic compounds were not detected in the ambient and pumped flows.

Publication Year 2009
Title Integrated analysis of flow, temperature, and specific-conductance logs and depth-dependent water-quality samples from three deep wells in a fractured-sandstone aquifer, Ventura County, California
DOI 10.3133/ofr20091023
Authors John H. Williams, Kevin D. Knutson
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Open-File Report
Series Number 2009-1023
Index ID ofr20091023
Record Source USGS Publications Warehouse
USGS Organization New York Water Science Center; Office of Ground Water