Use of field-applied quality control samples to monitor performance of a Goulden large-sample extractor/GC-MS method for pesticides in water

January 1, 2000

Since 1985, the Goulden large-sample extractor (GLSE) has been used to isolate a broad array of trace-organic contaminants from large volumes of water. In this study, field-applied quality control measures, including matrix and surrogate spikes and blanks, were used to monitor method performance from GLSE extraction through GC-MS analysis. The method was applied to the determination of multiple classes of pesticides isolated from 4- to 112-L filtered surface-water samples. Average recoveries of six surrogate compounds ranged from 84 ?? 18% for [2H10]diazinon to 15 ?? 13% for 4,4'-[2H8]DDT, the low recoveries for which were largely a result of unmonitored breakdown of this surrogate by the GC injection system. Field-matrix-spike samples were prepared by fortifying 10-L, 35-L, and 110-L filtered surface-water samples with 68 pesticides to amended concentrations of 11- to 50-ng/L each. Recoveries ranged from not detected to greater than 100%. Variability in pesticide recoveries from triplicate 10-L water samples collected at one site averaged 5.7% relative standard deviation and did not exceed 19%.Since 1985, the Goulden large-sample extractor (GLSE) has been used to isolate a broad array of trace-organic contaminants from large volumes of water. In this study, field-applied quality control measures, including matrix and surrogate spikes and blanks, were used to monitor method performance from GLSE extraction through GC-MS analysis. The method was applied to the determination of multiple classes of pesticides isolated from 4- to 112-L filtered surface-water samples. Average recoveries of six surrogate compounds ranged from 84 ?? 18% for [2H10]diazinon to 15 ?? 13% for 4,4???-[2H8]DDT, the low recoveries for which were largely a result of unmonitored breakdown of this surrogate by the GC injection system. Field-matrix-spike samples were prepared by fortifying 10-L, 35-L, and 110-L filtered surface-water samples with 68 pesticides to amended concentrations of 11- to 50-ng/L each. Recoveries ranged from not detected to greater than 100%. Variability in pesticide recoveries from triplicate 10-L water samples collected at one site averaged 5.7% relative standard deviation and did not exceed 19%.

Publication Year 2000
Title Use of field-applied quality control samples to monitor performance of a Goulden large-sample extractor/GC-MS method for pesticides in water
DOI 10.1080/03067310008034145
Authors W.T. Foreman, Paul M. Gates, G.D. Foster, F. A. Rinella, S. W. McKenzie
Publication Type Article
Publication Subtype Journal Article
Series Title International Journal of Environmental Analytical Chemistry
Index ID 70023189
Record Source USGS Publications Warehouse
USGS Organization National Water Quality Laboratory