Contraction scour at a bridge over Wolf Creek, Iowa Contraction scour at a bridge over Wolf Creek, Iowa
Contraction scour at the State Highway 14 bridge over Wolf Creek in south-central Iowa was caused by a large flood on September 14 and 15, 1992. The bridge is a 30.5-m, single-span steel structure supported by vertical-wall concrete abutments with wingwalls. Approximately 6 meters of scour resulted from the flood. The peak discharge was estimated by water-surface profile analysis to be 2...
Authors
Edward E. Fischer
Correlation of Ordovician rocks of northern Alaska Correlation of Ordovician rocks of northern Alaska
The Ordovician sequences presented in this report were chosen to cover a range of depositional and structural settings found in northern Alaska. Consequently, the quality of lithostratigraphic, paleontologic, and sedimentologic data is variable. Until 1982, Ordovician rocks in northern Alaska were known only from a few, widely separated localities. Since then, several hundred Ordovician...
Authors
Anita G. Harris, Julie A. Dumoulin, John E. Repetski, Claire Carter
Creating habitat for endangered species: use of restored riparian woodlands by least Bell's vireos Creating habitat for endangered species: use of restored riparian woodlands by least Bell's vireos
No abstract available at this time
Authors
B.E. Kus
Depth to pre-Cenozoic basement in Southwest Nevada Depth to pre-Cenozoic basement in Southwest Nevada
An iterative procedure based on gravity data, surface geology, and an estimated density-depth function was used to estimate the depth to pre-Cenozoic basement at Yucca Mountain and vicinity.
Authors
V.E. Langenheim, D. A. Ponce
Diet study of Atlantic sturgeon in marine waters Diet study of Atlantic sturgeon in marine waters
No abstract available at this time
Authors
J. Johnson, D. Dropkin
Digital photogrammetry at the U.S. Geological Survey Digital photogrammetry at the U.S. Geological Survey
The U.S. Geological Survey is converting its primary map production and revision operations to use digital photogrammetric techniques. The primary source of data for these operations is the digital orthophoto quadrangle derived from National Aerial Photography Program images. These digital orthophotos are used on workstations that permit comparison of existing vector and raster data with...
Authors
Clifford W. Greve
Discrete fracture modeling-ESF North Portal Area, Yucca Mountain Nevada Discrete fracture modeling-ESF North Portal Area, Yucca Mountain Nevada
Statistical parameters from three-dimensional fracture network and hydraulic parameters were developed to be used in site scale models. This approach utilizes geometric fracture models and assess their impact on flow characteristics and parameters. Laboratory and field-testing data will be integrated to calibrate the flow models and to determine sensitivities of the system.
Authors
Lawrence O. Anna
Effect of ground-water/surface-water interactions on nitrate concentrations in discharge from the South Platte River alluvial aquifer, Colorado Effect of ground-water/surface-water interactions on nitrate concentrations in discharge from the South Platte River alluvial aquifer, Colorado
Concentrations of dissolved nitrate in recharge-area water from a 200-km2 segment of the South Platte River alluvial aquifer near Greeley, Colorado, range from less than 0.1 to 58 mg/l as nitrogen, and the median concentration is 26 mg/l as nitrogen. Hydraulic-head data indicate that this nitrate-enriched ground water move toward the South Platte River. However, the median concentration...
Authors
P.B. McMahon, J.K. Böhlke
Effects of agricultural, industrial, and municipal pollutants on wetlands and wildlife and wildlife health Effects of agricultural, industrial, and municipal pollutants on wetlands and wildlife and wildlife health
Wetlands accumulate pollutants from adjacent areas through intentional discharge of sewage or industrial wastes, runoff of agricultural fertilizers and pesticides, and discharge from municipal storm drains. Coastal wetlands receive more pollutants indirectly as the endpoint for upland drainage systems and directly through petroleum spills and insect abatement. Wetlands that serve as...
Authors
Kathryn A. Converse
Effects of pulsating flow on current meter performance Effects of pulsating flow on current meter performance
Summarized are laboratory tests for current meter response to pulsating flows. Included are results for mechanical and electromagnetic water-current meters that are commonly used for stream gaging. Most of the vertical-axis and horizontal-axis types of mechanical meters that were tested significantly underregistered the mean flow velocity when the magnitude of the pulsating portion of...
Authors
Janice M. Fulford
Evaluation of frequency distributions for flood hazard analysis Evaluation of frequency distributions for flood hazard analysis
Many different frequency distributions and fitting methods are used to determine the magnitude and frequency of floods and rainfall. Ten different combinations of frequency distributions and fitting methods are evaluated by summarizing the differences in the 0.002 exceedance probability quantile (500-year event), presenting graphical displays of the 10 estimates of the 0.002 quantile...
Authors
Wilbert O. Thomas, Minoru Kuriki, Tadashi Suetsugi
Extending and expanding the life of older current meters Extending and expanding the life of older current meters
The EG&G Model 610 VACM and Model 630 VMCM are standards for ocean current measurements. It is simple to add peripheral sensors to the data stream of the VACM by use of add-on CMOS circuitry. The firmware control of the VMCM makes it virtually impossible to add sampling of additional sensors. Most of the electronic components used in the VACM are obsolete or difficult to replace and the...
Authors
W.J. Strahle, Marinna A. Martini