Clayton J Bosch (Former Employee)
Science and Products
Trolley Operated Automatic Discharge System (TOADS)—An automated system for horizontal profiling of water velocity and river discharge measurements
Hydroacoustics have revolutionized how the U.S. Geological Survey (USGS) measures streamflow by increasing the efficiency and quality of the measurement. However, the ability to determine the full range of streamflow at a streamflow-gaging station remains limited because in-person flow measurements still must be made by qualified personnel. As a result, streamflow during flood events typically is
Authors
Kevin K. Johnson, Clayton J. Bosch
Water Level, Temperature, and Bathymetry of the Grand Calumet River, Indiana-Illinois, 2017
The Grand Calumet River is located east of Chicago, Illinois and flows east to west across the Indiana-Illinois border to its confluence with the Little Calumet River. In 2017, a suite of water level, temperature, and bathymetric data were collected along the Grand Calumet River. Water level and water temperature were monitored continuously at five locations in the Grand Calumet River between late
USGS bathymetric and hydrodynamic survey of Lake Michigan nearshore near Ogden Dunes/Burns Harbor, Indiana
The US Army Corps of Engineers (USACE) is evaluating the placement of dredged material in the nearshore areas of Lake Michigan as a means to replenish sand at selected beaches. In order to elucidate the physical processes in the nearshore environment that transport and distribute sand to the beach, the USACE-Chicago District and the US Geological Survey (USGS) developed a plan for a beach nourishm
Acoustic Doppler current profiler velocity and discharge measurements collected in and near the lock chamber of Brandon Road Lock and Dam, Joliet, Illinois, USA in December 2014
Water velocities and discharge were measured in the lock chamber and immediately downstream of Brandon Road Lock on the Des Plaines River at river mile 286 on December 9-10, 2014 using Teledyne RDI Rio Grande 600 and 1200 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with a differential GPS receiver with submeter accuracy. These ADCP measurements were collected in supp
Science and Products
Trolley Operated Automatic Discharge System (TOADS)—An automated system for horizontal profiling of water velocity and river discharge measurements
Hydroacoustics have revolutionized how the U.S. Geological Survey (USGS) measures streamflow by increasing the efficiency and quality of the measurement. However, the ability to determine the full range of streamflow at a streamflow-gaging station remains limited because in-person flow measurements still must be made by qualified personnel. As a result, streamflow during flood events typically is
Authors
Kevin K. Johnson, Clayton J. Bosch
Water Level, Temperature, and Bathymetry of the Grand Calumet River, Indiana-Illinois, 2017
The Grand Calumet River is located east of Chicago, Illinois and flows east to west across the Indiana-Illinois border to its confluence with the Little Calumet River. In 2017, a suite of water level, temperature, and bathymetric data were collected along the Grand Calumet River. Water level and water temperature were monitored continuously at five locations in the Grand Calumet River between late
USGS bathymetric and hydrodynamic survey of Lake Michigan nearshore near Ogden Dunes/Burns Harbor, Indiana
The US Army Corps of Engineers (USACE) is evaluating the placement of dredged material in the nearshore areas of Lake Michigan as a means to replenish sand at selected beaches. In order to elucidate the physical processes in the nearshore environment that transport and distribute sand to the beach, the USACE-Chicago District and the US Geological Survey (USGS) developed a plan for a beach nourishm
Acoustic Doppler current profiler velocity and discharge measurements collected in and near the lock chamber of Brandon Road Lock and Dam, Joliet, Illinois, USA in December 2014
Water velocities and discharge were measured in the lock chamber and immediately downstream of Brandon Road Lock on the Des Plaines River at river mile 286 on December 9-10, 2014 using Teledyne RDI Rio Grande 600 and 1200 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with a differential GPS receiver with submeter accuracy. These ADCP measurements were collected in supp