Skip to main content
U.S. flag

An official website of the United States government

Data

The U.S. Geological Survey (USGS) currently operates and maintains data collection sites in the Central Midwest Water Science Center (Illinois, Iowa, and Missouri) for acquiring information about surface water, ground water, water quality, and precipitation to provide necessary information for our cooperators in this Center.

 

Filter Total Items: 217

Spatial distribution of depth-averaged velocity measured in the Wabash River near West Lafayette, IN (June 26-27, 2012 and June 17-18, 2013) Spatial distribution of depth-averaged velocity measured in the Wabash River near West Lafayette, IN (June 26-27, 2012 and June 17-18, 2013)

These data were collected using a 2 mHz TRDI StreamPro acoustic Doppler current profiler (ADCP) in 2012 and a 1200 kHz Rio Grande ADCP in 2013, both deployed from a moving boat. The data were georeferenced with a Hemisphere Crescent A100 differential Global Positioning System (GPS) receiver with submeter accuracy. The data have been depth-averaged over the entire measured portion of the...

Rhodamine WT dye concentration profiles measured at fixed stations in the Brandon Road Lock chamber near Rockdale, Illinois (October 20, 2015) Rhodamine WT dye concentration profiles measured at fixed stations in the Brandon Road Lock chamber near Rockdale, Illinois (October 20, 2015)

A Turner Designs C3 submersible fluorometer was deployed in the Brandon Road Lock chamber (BRLD) near Rockdale, Illinois, to measure Rhodamine WT dye concentrations during a U.S. Geological Survey dye study conducted on October 20, 2015. The lock chamber at BRLD was dyed with 4 liters of Rhodamine WT dye during a routine filling procedure. Measurements of dye concentration profiles were...

Water surface elevation in the Brandon Road Lock chamber near Rockdale, Illinois (October 19-21, 2015) Water surface elevation in the Brandon Road Lock chamber near Rockdale, Illinois (October 19-21, 2015)

An Insitu Level Troll 500 was deployed in the Brandon Road Lock chamber (BRLD) near Rockdale, Illinois between 12:09 Central Daylight Time (CDT) on October 19, 2015 and 14:57 CDT October 21, 2015 to monitor water-surface elevation in the lock chamber during a U.S. Geological Survey dye study conducted on October 20, 2015. The duration of the deployment included a day prior to and a day...

Rhodamine WT dye concentrations measured at fixed locations in the Des Plaines River near Brandon Road Lock and Dam near Rockdale, Illinois (October 20-21,2015) Rhodamine WT dye concentrations measured at fixed locations in the Des Plaines River near Brandon Road Lock and Dam near Rockdale, Illinois (October 20-21,2015)

Five Turner Designs C3 submersible fluorometers were deployed in the Des Plaines River downstream of the Brandon Road Lock and Dam (BRLD) near Rockdale, IL, to measure Rhodamine WT dye concentrations during a U.S. Geological Survey dye study conducted on October 20-21, 2015. The lock chamber at BRLD was dyed with 4 liters of Rhodamine WT dye during a routine filling procedure...

Spatial distribution of Rhodamine WT dye concentration measured in the Des Plaines River near Brandon Road Lock and Dam near Rockdale, Illinois (October 20-21, 2015) Spatial distribution of Rhodamine WT dye concentration measured in the Des Plaines River near Brandon Road Lock and Dam near Rockdale, Illinois (October 20-21, 2015)

Two survey boats equipped with differential Global Positioning System (GPS) receivers and Turner Designs C3 submersible fluorometers were used to survey the spatial distribution of the Rhodamine WT dye in the Des Plaines River downstream of the Brandon Road Lock and Dam (BRLD) near Rockdale, Ilinois. Mapping of the dye plume commenced after the lock chamber at BRLD was dyed with 4 liters...

Acoustic Doppler current profiler velocity data collected in the approach channel of Brandon Road Lock and Dam in 2015 Acoustic Doppler current profiler velocity data collected in the approach channel of Brandon Road Lock and Dam in 2015

Water velocities were measured in the Des Plaines River from approximately river mile 286 to river mile 284 on October 1921, 2015 using Teledyne Rio Grande 1200 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with differential GPS receivers with submeter accuracy. These velocity data were collected in support of the US Army Corps of Engineers Great Lakes and...

Velocity Mapping with ADCP in the Illinois River and Des Plaines River Velocity Mapping with ADCP in the Illinois River and Des Plaines River

Water velocities were measured along the Illinois and Des Plaines Rivers using a Teledyne Rio Grande 1200 kHz acoustic Doppler current profiler (ADCP). ADCP data were collected in reciprocal pairs along crosssections and along approximately streamwise-oriented lines between crosssections at the following locations: (1) the Dresden Island Pool of the Des Plaines River on May 14, 2013 and...

Velocity profiling in the Chicago Sanitary and Ship Canal near the US Army Corps of Engineers Electric Dispersal Barrier near Romeoville, Illinois Velocity profiling in the Chicago Sanitary and Ship Canal near the US Army Corps of Engineers Electric Dispersal Barrier near Romeoville, Illinois

On August 31, 2015, USGS Illinois Water Science Center staff deployed a 2000 kHz side-looking acoustic Doppler velocity meter (ADVM) in the Chicago Sanitary and Ship Canal (CSSC) at the Electric Dispersal Barrier System (EDBS). These data were collected as a fully loaded commercial barge tow traversed the EDBS and passed the ADVM three times, and as several smaller vessels and an...

Acoustic Doppler current profiler velocity data collected in the Calumet Harbor, Illinois in 2015 and 2016 Acoustic Doppler current profiler velocity data collected in the Calumet Harbor, Illinois in 2015 and 2016

Water velocities were measured in the Calumet Harbor for 5 dates in 2015 and 2016 using Teledyne Rio Grande 600 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with differential GPS receivers with submeter accuracy. These velocity data were collected in cooperation with the US Army Corps of Engineers-Chicago District. ADCP data were collected on the following...

Water-quality distribution in the Chicago Sanitary and Ship Canal, USGS towed multiparameter sonde, Daily tow data files (Feb. 25-27, 2010 and March 2-3, 2010) Water-quality distribution in the Chicago Sanitary and Ship Canal, USGS towed multiparameter sonde, Daily tow data files (Feb. 25-27, 2010 and March 2-3, 2010)

These data files include georeferenced water-quality data with associated time stamps (Central Standard Time) for basic water-quality parameters as measured by a towed multiparameter sonde (YSI 6920 sonde) from a manned boat in the Chicago Sanitary and Ship Canal. Data were collected on February 25-27, 2010, and again on March 2-3, 2010. The data collected in February 2010 had the sonde...

Acoustic Doppler current profiler velocity data collected in the Chicago Sanitary and Ship Canal in 2010 and 2011 in support of the interbasin transport study for invasive Asian carp Acoustic Doppler current profiler velocity data collected in the Chicago Sanitary and Ship Canal in 2010 and 2011 in support of the interbasin transport study for invasive Asian carp

Water velocities were measured in the Chicago Sanitary and Ship Canal (CSSC) in 2010 and 2011 using Teledyne Rio Grande 600 kHz and 1200 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with differential GPS receivers with submeter accuracy. Data were processed using the Velocity Mapping Toolbox (Parsons et al., 2013). Any data assigned a value of "-9999" are...

Hydroacoustic measurements of velocities in and near the rake-to-box junction gap of a moving, fully-loaded commercial barge tow Hydroacoustic measurements of velocities in and near the rake-to-box junction gap of a moving, fully-loaded commercial barge tow

In August 2015, water velocities around a fully-loaded commercial barge tow were measured as the barge tow traveled upstream through the Chicago Sanitary and Ship Canal from a starting position in Lockport Pool, and passed through the Electric Dispersal Barrier System at river mile (RM) 296 near Romeoville, IL. Velocity measurements were made in and alongside the gap formed by the...
Was this page helpful?