Quantitation of estrogens in water, alone and in combination with atrazine, using two chemically-activated luciferase expression, CALUX, bioassays and quadrupole-time of flight ultraperformance liquid chromatography/mass spectrometry, UPLC-MS
December 15, 2022
This data describes the relative luminescence units and relative fluorescence units of lysates of two estrogen responsive chemically-activated luciferase expression human breast VM7Luc4E2 and VM7LucERbc9 cells which were exposed for 24 hours to estrone and 17beta-estradiol dilutions alone and in mixture with atrazine or water extracts collected from dilutor tanks during a fish exposure study utilizing estrone and atrazine. The data for corresponding measurements of estrone in the water extracts by liquid chromatography-mass spectrometry are also shown. This data also describes relative fluorescence units of bovine serum albumin standards which were used to convert the relative fluorescence units of the cell lysates to protein with which to normalize the relative luminescence units of the cell lysates.
Citation Information
Publication Year | 2022 |
---|---|
Title | Quantitation of estrogens in water, alone and in combination with atrazine, using two chemically-activated luciferase expression, CALUX, bioassays and quadrupole-time of flight ultraperformance liquid chromatography/mass spectrometry, UPLC-MS |
DOI | 10.5066/P98PC526 |
Authors | Jennifer C Brennan, Abigail N Henke, Robert W Gale, Donald E Tillitt |
Product Type | Data Release |
Record Source | USGS Asset Identifier Service (AIS) |
USGS Organization | Columbia Environmental Research Center |
Rights | This work is marked with CC0 1.0 Universal |
Related
Comparison of two estrogen chemically activated luciferase expression cell bioassays to liquid chromatography–mass spectrometry for quantifying estrone in water samples
Chemically activated luciferase expression (CALUX) cell bioassays are popular tools for assessing endocrine activity of chemicals such as certain environmental contaminants. Although activity equivalents can be obtained from CALUX analysis, directly comparing these equivalents to those obtained from analytical chemistry methods can be problematic because of the complexity of endocrine...
Authors
Jennifer C. Brennan, Abigail Henke, Robert Gale, Diane K. Nicks, Donald Tillitt
Robert Gale, PhD (Former Employee)
Research Chemist
Research Chemist
Donald Tillitt, PhD
Research Toxicologist
Research Toxicologist
Email
Phone
Related
Comparison of two estrogen chemically activated luciferase expression cell bioassays to liquid chromatography–mass spectrometry for quantifying estrone in water samples
Chemically activated luciferase expression (CALUX) cell bioassays are popular tools for assessing endocrine activity of chemicals such as certain environmental contaminants. Although activity equivalents can be obtained from CALUX analysis, directly comparing these equivalents to those obtained from analytical chemistry methods can be problematic because of the complexity of endocrine...
Authors
Jennifer C. Brennan, Abigail Henke, Robert Gale, Diane K. Nicks, Donald Tillitt
Robert Gale, PhD (Former Employee)
Research Chemist
Research Chemist
Donald Tillitt, PhD
Research Toxicologist
Research Toxicologist
Email
Phone