Banding

Landsat data are systematic, geometric, radiometric, and terrain corrected to provide the highest quality data to the user communities. Occasionally, anomalies occur and artifacts are discovered that require research and monitoring. 

Several artifacts are known to cause the effect described as Banding in Landsat 4-5 Thematic Mapper (TM) data.

Return to Landsat Known Issues Overview

 

These images show Banding in Landsat 4-5 Thematic Mapper (TM) data.  

Scan Correlated Shift (SCS) causes banding by forcing each scan to randomly choose one of the two or more bias states. This banding has a stable magnitude across each scan.

Banding due to Scan Correlated Shift (SCS) in Landsat 5 TM Band 3
Banding due to Scan Correlated Shift (SCS) in Landsat 5 TM, Band 3. 

Memory Effect (ME) causes banding-like patterns that change in magnitude across a scan. ME is caused by a large radiance transition in the scanning direction, from bright target to dark or from dark target to bright, either in the imagery or in the IC region of the data. For ME to create banding, the target is usually many scan lines in size, and if the target is in the imagery, the banding may visibly change over the bright target.

Banding due to Memory Effect (ME) in Landsat 5 TM Band 3
Banding due to Memory Effect (ME) in Landsat 5 TM, Band 3. 

Calibration Error Banding, also known as "True Banding" or "Sweep Striping," is caused by errors in calibration algorithms that treat forward and reverse scans separately, so that one direction of scan has a different bias than the other. These errors create a Banding artifact that is stable across the scan and consistently alternates between high and low bias. True Banding is rare in TM data and is corrected when found, but it may be visible in data from older instruments.

  Magnitude Appearance
Scan Correlated Shift (SCS) stable across a scan randomly bright or dark
Memory Effect (ME) changes across a scan alternately bright and dark
Calibration Error Banding stable across a scan alternately bright and dark

More than one of these artifacts can affect an instrument, causing banding of a complex character that may be difficult to diagnose with a cursory visual inspection. All forms of banding are known artifacts. They are all correctable and not cause for concern.